current location: IDFC Air Conditioning Unit
THe IDFC air conditioning system is composed of a fresh air system which provides treated air to AC rooms through medium and low pressure single duct system and a return air system which adopts IDFC AC unit to treat return air.IDFC AC unit can ensure the comfort and indicidauation of each cabin.
Model Description:
"I" : Intelligent
D: Decentralized
F: Fan
C: Coil
Main components:
It is composed of fresh air air conditioner, IDFC unit, terminal device, air duct system, control system, refrigeration device, shutoff valve, fresh air inlet and other parts.
System functions:
Fresh air treatment: in summer, fresh air is cooled in the air conditioner. In winter, fresh air is heated in the air conditioner. According to different types of ships and actual demand, enthalpy humid exchanger can be selected as the component of fresh air conditioner to further achieve the purpose of energy saving.
IDFC unit air treatment: air is sent to the air supply section of THE IDFC unit at one time in the cabin, bypassed from the fan, or mixed with circulating air after the IDFC unit.
Air distribution: Fresh air is processed by the fresh air conditioner according to the current setting before distribution, distributed to the cabin area through the spiral air duct system, and then into the air conditioning cabin through the IDFC unit.
System advantages:
IDFC air conditioning system is very suitable for the ship with more living rooms and personnel. For these ships, IDFC air conditioning system can effectively save space in the installation of air conditioners and duct systems, so as to achieve the purpose of air conditioning system energy saving, comfortable and personalized cabin environment.
System features:
Good comfort: it can meet the temperature control requirements of different cabin users for a single cabin.
Low noise: thanks to the use of low noise fans and stepless transmission, as well as IDFC unit enclosure insulation. In addition, there is no need to install additional mufflers in the duct system.
Precise cabin temperature control: Precise air environment control and energy saving optimization are realized through built-in microprocessing controller.
Energy saving: reduce excess fresh air through reasonable fresh air distribution; IDFC unit frequency conversion control and intelligent control system to achieve the purpose of energy saving.
Space saving: because only the fresh air conditioner is set, compared with the all-air central air-conditioning system, the number of air conditioners is reduced, and the number and size of air supply and return ducts are reduced, which saves the space of the air conditioner room and the space required for the arrangement of air ducts.
Flexible overall design layout: IDFC unit size is small, easy to disperse layout.
Air volume balance and stability: the air conditioning system of the residential cabin adopts fresh air conditioner with constant air volume to supply air, matching with the mechanical ventilation system of the whole ship.
Easy maintenance: The IDFC unit has few maintenance components and reasonable layout. You can directly maintain the IDFC unit in the aisle.
Sales consulting :
0523-87592868Complaints Hotline :
0523-87599555After sale :
0523-87598760